Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Notice: Trying to access array offset on value of type null in /home/melsytech/eng.melsytech.com/docs/media/zoo/applications/jbuniversal/framework/libs/less.gpeasy.php on line 2049
Deprecated: Function create_function() is deprecated in /home/melsytech/eng.melsytech.com/docs/administrator/components/com_zoo/tables/category.php on line 139
Pulsed Diode-Pumped Nd:YAG + KTP system
A solid state quasi-continuous laser system with 808nm diode pumping of Nd:YAG rod (1064nm) and second harmonic generation based on KTP rod (532nm) and Q-switched modes at both 1064 and 532nm wavelengths.
Cosmetology / Aesthetic Medicine
Industrial - Engraving/ Cutting/ Marking
-
Two-wave systems
Description Wave length, nm Operation mode Pulse energy, mJ Pulse length, ns Pulse repetition rate, Hz Pumping power, W I20kG-NDYAGKTP-TA 1064 Free running 20J ≤40ms ≤100 20,000 1064 Q-Switch 1.1 7 ≤100 20,000 532 Q-Switch 0.5 7 ≤100 I7kG-NDYAGKTP-TA 1064 Free running 10J ≤40ms ≤100 7,000 1064 Q-Switch 300 7 ≤100 7,000 532 Q-Switch 200 7 ≤100 I3.5kG-NDYAGKTP-TA 1064 Free running 5J ≤40ms ≤100 3,500 1064 Q-Switch 150 7 ≤100 3,500 532 Q-Switch 80 7 ≤100 I3.5kG-NDYAGKTP-TP 1064 Free running 6J ≤40ms ≤100 3,500 1064 Q-Switch 200 25-40 ≤100 3,500 532 Q-Switch 100 25-40 ≤100 Single wave systems
Description Wave length, nm Operation mode Pulse energy, mJ Pulse length, ns Pulse repetition rate, Hz Pumping power, W I14kG-NDYAG 1064 Free running 70J ≤50мсms ≤100 14,000 I10kG-NDYAG 1064 Free running 50J ≤50ms ≤100 10,000 I3.5kG-NDYAG 1064 Free running 17J ≤50ms ≤100 3,500 -
- safe and rigid housing
- VCSEL diode pumping
- flat top beam profile
Configuration:
- a laser gain module
- a crystal rod
- a driverSupply options:
- laser gain module + laser diode driver
- laser gain module only (driver si provided by Customer)
- customizeddesign - safe and rigid housing